Technical guide

No, abadis canisters do not need to be replaced after each use.

The suction bag is made of polyethylene (PE) and the canisters are made of polycarbonate.

These filters are made of nanoparticles and polymer and composite materials and  makhazen tebi abadis Company is introduced as the first manufacturer of these filters in Iran.

Abadis Medical canisters Company is the first manufacturer of these filters in Iran.

Absorbent powder in Abadis suction bags causes jelly of liquid materials inside the bags, which makes it easy to carry and also in case of overflow or torn bag, causes better collection of liquids inside the bag.

Suction bags can be replaced after full filling and be sure not to move the suction bags of different patients together to better control the infection.

1) Don’t use a disposable suction bag that fits the size of the canister.

2) suction Bags shouldn’t be replaced at least once every 24 hours if used.

3) Use the suction bags more than once.

This product will be out of warranty if the Abadis disposable suction bag isn’t used properly in the above cases.

1) Use disinfectants and water in the ratio of 1 to 10 to wash the suction canisters.

2) Roll the suction canisters for 10 minutes in the solution mentioned above; Be careful not to put the canisters in solution for more than the mentioned time because it will damage the canisters.

3)after that place the canister on a  dry towel and allow the canisters to dry completely.

4)Abadis suction canisters can be washed in autoclave up to 120 ° C.

5)The canister must be replaced if there are any cracks or fractures.

How to wash the canisters is only acceptable as above, and if the washing is not done in this way, it will be out of warranty.

* Keep in mind that Abadis suction canisters only need to be washed if there is contamination.

When the paper inside the antibacterial filter changes color, the filter must be replaced, and if the filter is changed.

flow stopper filter should be replaced when fluids penetrate the filter surface or the suction pressure drops, and it is best to replace the circuit breaker filter every month for proper operation.

Yes, wall and portable brackets in both aluminum and plastic can be washed up to a maximum temperature of 95 degrees.

Abadis trolley is out of warranty in case of severe impact.

Abadis suction canister will be out of warranty if it is  damaged.

Abadis regulator will be out of warranty if it is hit and the device is damaged.

product name

warranty

suction bag

Abadis disposable suction liner bag if have any problems can be replaced up to one year

suction canister

Abadis disposable suction canister if have any problems can be replaced up to one year

Trolley

Abadis trolleys if have any problems can be replaced up to 6 months After that, the repair  is possible at a cost.

wall bracket

Abadis wall bracket if have any problems can be replaced up to 3 year

Rail bracket

Abadis rail bracket if have any problems can be replaced up to 3 year

T connector


T connector in case of failure has a lifetime replacement warranty for free.

connector


  abadis connector in case of failure has a lifetime replacement warranty for free.

Regulator

Abadis regulator if have any problems can be replaced up to 6 months After that, the repair  is possible at a cost.

Wall Suction

wall suction if have any problems can be replaced up to 6 months After that, the repair  is possible at a cost.

Shipping

In each carton, there are 45 disposable suction bags for every 3 sizes

Abadis disposable suction bags are produced in three sizes of one, two and three liters.

  • Dimensions of 1 liter carton 57/5 * 42/5 * 44
  • Dimensions of 2 liter carton 57/5 * 42/5 * 44
  • Dimensions of 3 liter carton 49 * 49 * 49
Row
vehicle
Number
1
Pick-up truck
52
2
Truck
200
3
20 foot container
298
4
40 foot container
596

Order Guide

You can make your request by filling out the contact form with us or contact the installation unit of Abadis Medical Tanks Company.

  1. Complete the contact form with us or contact the sales experts and register the request
  2. Pre-invoice confirmation by the customer
  3. Deposit money
  4. Sending products

Installation

  1. According to the shape of the silicone tube, we connect it from the regulator or suction device to the T connector on the canister.
  2. On the other hand, connect the T connector silicone tube to the connection of the connection and connect the connection on the vacuum part on the door.
  3. Connect the suction tube (suction tube) to the patient (patient) part and perform the suction operation from the suction tube (suction tube).

  1. From the connection of T connector on the canister
  2. Connection and non-leakage in silicone hoses related to suction device and T connector
  3. Connecting the suction tube to the patient

Yes, you can see the following image:

  1. According to the picture of the silicone tube, we connect it from the regulator or suction device to the Tconnector on the canister with the initial suction bag (pre).
  2. On the other hand, we connect the T connector of silicone tube to the next canister, which contains the Final (or final) bag and has a flow stopper filter.
  3. On the other hand, we connect the Tconnector of the same canister with a silicone tube to the vacuum part on the door.
  4. From the patient’s connection on the lid of the same canister, we connect it to the vacuum part of the previous canister.
  5. Connect the suction tube (suction tube) to the patient (patient) part and perform the suction operation from the suction tube (suction tube).

Up to four canisters can be connected in a series.